Global Fire Conventional Panel ORION 2-4-8
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
TECHNICAL SPECIFICATIONS | |
SUPPLY SPECIFICATION | DETAILS |
PRIMARY SUPPLY VOLTAGE - IN | 230 +10% -15% V AC |
PRIMARY SUPPLY VOLTAGE - OUT | 28.5 V DC nominal |
PRIMARY SUPPLY CURRENT - OUT | 1.7 A @ 28.5 V DC nominal (max.) |
SECONDARY SUPPLY VOLTAGE | 21.0 min. - 27.2 max. V DC - BAT charger o/p 28 V DC |
SECONDARY SUPPLY CURRENT OUTPUT | 1.1 Amp Maximum @ 200C |
INTERNAL BATTERY CAPACITY - MAXIMUM | 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries |
MAINS FUSE | 4 A -250 V Slow Blow - 20 mm |
BATTERY FUSE | 1.6 Amp - Resettable |
DETECTION CIRCUIT SPECIFICATION | |
NUMBER OF CIRCUITS | 2,4 or 8 |
ZONE CURRENT - QUIESCENT / ALARM | 4 mA / 60 mA - Maximum |
MAX. CABLE RESISTANCE / CAPACITANCE | 40 Ohms / 0.470 uF |
END OF LINE MONITORING | Active EOL - 10uF/50V Bipolar Electrolytic Aluminium Capacitor |
BS-5839 DETECTOR REMOVAL COMPLIANT | YES provided diodes are fitted to detector base |
DEVICES PER ZONE | 32 Maximum - EN54 pt.2 |
ALARM RESISTANCE VALUE | 270 - 1000 Ohms |
SOUNDER CIRCUIT SPECIFICATION | |
CURRENT OUTPUT | 2 outputs w/ 500mA max. current drive per circuit - fully monitored |
ALARM VOLTAGE / END OF LINE RESISTOR | 27.5 V DC Nominal / 10 K Ohms - 1/4 Watt |
AUXILIARY OUTPUTS SPECIFICATION | |
AUXILIARY RELAY OUTPUT | 1 Fire (COM |
RELAY CONTACT RATING | 50 V DC |
REMOTE INPUT SPECIFICATION | |
EVACUATION (CC) - DAY/ NIGHT MODE | Non-Latching |
RESET | Non-Latching |
MECHANICAL & OPERATING SPEC. | |
HUMIDITY | Max 95% RH Non-Condensing |
PROTECTION | IP30 |
OPERATING TEMPERATURE | -10ºC to 50ºC |
WEIGHT | 1.7 Kg - 7 Kg (inc. 2 x 7 AH 12 V bat.) |
DIMENSIONS | 273 (L) x 107 (W) x 404 (H) mm |
COLOUR | Red & White |
Description
ORION
Conventional Fire Detection Panel
The ORION conventional control panel range offers a creatively designed and visually pleasing solution for
smaller cost-conscious projects demanding simplicity of operation. Versions available include 2, 4 and 8 zone
panels and two styles of repeater.
The outstanding programmable features included in this panel range contradict the facilities commonly available
in this type of panel and include: programmable time delay by zone, Day/Night mode, selectable non-latching
zones and coincidence detection.
Operation is extremely intuitive, offering simple control and one-button disablement facilities, as well as the one
man test mode which provides simple and efficient testing of the system.
Advanced configuration solutions include the following: a dedicated RS232 communication interface allowing
connection of up to 4 remote repeater panels, addressable loop interface modules and multiplexed zonal output
relays; giving one of the most highly advanced levels of system integration and compatibility existing on the
market at this level.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Global Fire Conventional Panel ORION 2-4-8” Cancel reply
Related Products
-
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation. -
0 out of 5
Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm² -
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE