Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
Power supply specification
Main supply voltage: 15Vdc to 26Vdc
Standby consumption 600 μA
Cable Connection: Max 2,5mm²
Alarm consumption : 0.6mA to 11mA (depending on tones)
Mechanical characteristics
Unit weight: 200g
Unit dimensions (in mm): Diam. 109mm Height 84mm
Unit row material: ABS
Unit colour: Red & White
Protection class: IP21C
Climatic characteristics
Operating temperature: 0°C to 50°C
Storage temperature: +10°C to +50°C
Operating relative humidity: 90%
Storage relative humidity: 85%
Description
AVSA.05 is an addressable sounder device build to be connected to a fire detection system (FDS). It is allocated and identified by an address; AVSA.05 is designed to be directly operational from a loop or line of a panel managing the 05 range protocol, it can be monitored and activated individually. Its round shape allows to be used on walls and ceilings. Every device has an integrated loop isolator. The choice of colours (white and red) allows a good sobriety of installation on any surfaces. AVSA.05 works with a piezoelectric cell that warrants a low loop or line consumption current. Its side hearings ensure an excellent sound broadcasting. The addressable sounder AVSA is certified with the standards EN 54-3 and EN 54-17.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Addressable Indoor sounder AVSA05R” Cancel reply
Related Products
-
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software
-
0 out of 5
Conventional Sounder VALKYRIE CS
VALKYRIE CS
Conventional Wall Mount Sounder/ Beacon
The VALKYRIE CS is a wall mounted Conventional Sounder/ Beacon with low power consumption. Four different
tones are available and selected using DIL switches 1 and 2.
Both continuous and pulsing outputs are provided via separate negative supply connections allowing for the
presence of differentiated evacuation and alert sounds. -
0 out of 5
TS1000
Tripod turnstiles are compact and cost-effective entrance solutions. Designing for smooth and silent operation, reducing power consumption, wear and tear. It is suitable for areas with a high traffic.
The TS1000 series, our stainless steel compact version,offer high operating reliability in a small casework, ideal for sites where space is an issue. By receiving a signal from the access control system, or pushing button, it allows the entry of one person in a time. Entering into different directions are electronically controlled. Default mode is to lock the mechanism until a valid authorization signal is received. IIf you want to set one side free, you can adjust the mechanism. In case of emergency, the horizontal arm will drop to allow free passage.
-
0 out of 5
Global Fire Conventional Panel ORION 2-4-8
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
-
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
Reviews
There are no reviews yet.