Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm²
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm²
Power supply specification
Main supply voltage: 13V to 27Vdc
Nominal main supply voltage 20Vdc
Quiescent current 20-30µA
Alarm current: 32ma
Mechanical characteristics
Unit weight: 130g
Unit dimensions (in mm): H:55, D:104
Unit row material: ABS
Unit colour: White
Protection class: IP32
Climatic characteristics
Operating temperature: -10°C to +50°C
Storage temperature: +10°C to +50°C
Operating relative humidity: ≤ 93%
Storage relative humidity: ≤ 85%
Description
Both Temperature heat detectors analyze the ambient temperature by the means of thermistor type CTN.
TSC05 (static heat detector) is either classified A1S or BS according to EN54-5 standard:
TSC05-A1S: static T°=62°C±3°C
TSC05-BS: static T°=75°C±5°C
TRC05 (static + rate of rise detector) is especially adapted for average ambient temperature conditions
under +10°C. TRC05 is classified A1R according to EN54-5 standard:
Static T°=62°C±3°C
ΔT°>9°C/min
Both types include a developed technology (microprocessors, smd components) which means precision
and high reliability. A specific head detection fixed by a single ceiling base.
12V version of TRC05 & TSC05 detectors is also available for security type systems
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Conventional heat detectors TS/TR” Cancel reply
Related Products
-
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control -
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
Reviews