Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
Power supply specification
Main supply voltage: 15Vdc to 26Vdc
Standby consumption 600 μA
Cable Connection: Max 2,5mm²
Alarm consumption : 0.6mA to 11mA (depending on tones)
Mechanical characteristics
Unit weight: 200g
Unit dimensions (in mm): Diam. 109mm Height 84mm
Unit row material: ABS
Unit colour: Red & White
Protection class: IP21C
Climatic characteristics
Operating temperature: 0°C to 50°C
Storage temperature: +10°C to +50°C
Operating relative humidity: 90%
Storage relative humidity: 85%
Description
AVSA.05 is an addressable sounder device build to be connected to a fire detection system (FDS). It is allocated and identified by an address; AVSA.05 is designed to be directly operational from a loop or line of a panel managing the 05 range protocol, it can be monitored and activated individually. Its round shape allows to be used on walls and ceilings. Every device has an integrated loop isolator. The choice of colours (white and red) allows a good sobriety of installation on any surfaces. AVSA.05 works with a piezoelectric cell that warrants a low loop or line consumption current. Its side hearings ensure an excellent sound broadcasting. The addressable sounder AVSA is certified with the standards EN 54-3 and EN 54-17.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Addressable Indoor sounder AVSA05R” Cancel reply
Related Products
-
0 out of 5
Global Fire Conventional Panel ORION 2-4-8
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
TD-3332H2
Features
Support 8 / 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 / 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
-
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management