Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version
Power supply specification
Main supply voltage: 12V to 28Vdc
Nominal main supply voltage 24Vdc
Quiescent current 0.15 ma
Alarm current: 5mA @ 24Vdc
Mechanical characteristics
Unit weight: 170g
Unit dimensions (in mm): 99 x 98 x 49
Unit row material: ABS
Unit colour: Red
Protection class: IP33
Climatic characteristics
Operating temperature: -10°C to +60°C
Storage temperature: +10°C to +50°C
Operating relative humidity: ≤ 93%
Storage relative humidity: ≤ 85%
Description
DMA05 manual call points are devices of transmission of an alarm status towards an addressable indicating panel.
This action is carried out by the operator through mechanical pressure on the window located in the front.
Return to the normal status can be done only after local resetting using a special key.
Moreover the addressable version of manual call point integrates on every device a switch providing the function of line
isolator. This function is assured only in association with the HEPHAIS range panels which are equipped with boards
managing the loop/line. The function “Isolator of line” makes possible the isolation of sections in short-circuit (Shortcircuit
between 2 conductors of the connecting cable), located between 2 devices equipped with switch.
Usually, connection is carried out with shielded cable from 0, 6mm² to 1,5mm². Shield must be protected by an insulator
tape in order to avoid any short-circuit.
Call point also exits in waterproof IP65 version BA95S
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Addressable manual call point DMA05” Cancel reply
Related Products
-
0 out of 5
TS1000
Tripod turnstiles are compact and cost-effective entrance solutions. Designing for smooth and silent operation, reducing power consumption, wear and tear. It is suitable for areas with a high traffic.
The TS1000 series, our stainless steel compact version,offer high operating reliability in a small casework, ideal for sites where space is an issue. By receiving a signal from the access control system, or pushing button, it allows the entry of one person in a time. Entering into different directions are electronically controlled. Default mode is to lock the mechanism until a valid authorization signal is received. IIf you want to set one side free, you can adjust the mechanism. In case of emergency, the horizontal arm will drop to allow free passage.
-
0 out of 5
D-link 05 port Gigabit switch Model: DGS-1005A
High-Speed Networking
Gigabit ports allow you to connect up to five devices
for fast file transfers and smooth media streaming
Save Energy Automatically
EEE compliance reduces energy consumption
without sacrificing performance while cutting down
on your power bill
Eco-Friendly and Economical
Economical yet innovative design runs cool and quiet,
making for an unobtrusive addition to the workplace Connectivity
Five Gigabit Ethernet LAN ports for high-speed
wired connections
Cable Diagnostics Function notifies users of
cable conditions through product LEDs
Green Ethernet Features
Reduces power to a port when no link is
detected
Adjust power to a port by detecting the length
of the connected Ethernet cable -
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Reviews
There are no reviews yet.