Global Fire Addressable Panel JUNO NET
- Fully expandable system from 1-96 Loops with distributed intelligence for added security
- Up to 256 devices per loop (TBA)
- Up to 96 Loop sounders with 32 individually programmable addresses per Loop
- Compatible with major analogue addressable communications protocols
- 2 Fire output changeover relays and 1 Fault output relay (NC)
- Open collector outputs for Fire, Fault and pre-alarm remote indication
- 2 fully monitored sounder outputs on main panel and each sub panel
- Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
- Redundant network communication via RS485, TCP/IP & Fiber Optics
- 384 programmable zones
- 512 fully programmable sounder and I/O groups
- Event Log 2000 entries FIFO
- Backlit LCD display 4 row * 40 characters
- Multiple programming options, onboard keypad, Remote IR(optional), PS2 Keyboard and GFE Connector software
- Windows™ based PC Graphics package ODYSSEY for alarm management and reporting(Optional)
- Multiple Language support (menu selectable)
- MODBUS (ASCII & RTU) and BMS support
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
- Fully expandable system from 1-96 Loops with distributed intelligence for added security
- Up to 256 devices per loop (TBA)
- Up to 96 Loop sounders with 32 individually programmable addresses per Loop
- Compatible with major analogue addressable communications protocols
- 2 Fire output changeover relays and 1 Fault output relay (NC)
- Open collector outputs for Fire, Fault and pre-alarm remote indication
- 2 fully monitored sounder outputs on main panel and each sub panel
- Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
- Redundant network communication via RS485, TCP/IP & Fiber Optics
- 384 programmable zones
- 512 fully programmable sounder and I/O groups
- Event Log 2000 entries FIFO
- Backlit LCD display 4 row * 40 characters
- Multiple programming options, onboard keypad, Remote IR(optional), PS2 Keyboard and GFE Connector software
- Windows™ based PC Graphics package ODYSSEY for alarm management and reporting(Optional)
- Multiple Language support (menu selectable)
- MODBUS (ASCII & RTU) and BMS support
TECHNICAL SPECIFICATIONS | 1 - 4 LOOPS | 4 - 13 LOOPS |
LOOPS | 1 to 4 loops - Max 275 mA per loop | 4 to 13 loops - Max 275 mA per loop |
SOUNDER OUTPUTS | 2 at 28 V DC / 500 mA each | 4/6/8 24 V DC / 500 mA each |
AUX. RELAYS FIRE | 2 rated 50 VAC / DC 1A resistive | 2 rated 50 VAC / DC 1A resistive |
AUX. RELAY FAULT | 1 rated 50 VAC / DC 1A resistive | 1 rated 50 VAC / DC 1A resistive |
AUX SUPPLY OUTPUT | 28 V DC; 2x230 mA | 28 V DC; 2x230 mA |
ADDITIONAL OUTPUTS | Multiplexed up to 384 Zones | Multiplexed up to 384 Zones |
PRIMARY SUPPLY | 230 +10% -15% V AC | 230 +10% -15% V AC |
SECONDARY SUPPLY | 28 V DC Nominal | 28 V DC Nominal |
POWER SUPPLY RATING | 65 W (1-3 Loop) - 150 W (4 Loop) | 150 W (4-6 Loop) - 200 W (7-13 Loop) |
QUIESCENT CURRENT (NO DEVICES) | 130 mA (1-3 Loop) - 180 mA (4 Loop) | 130 mA + 90 mA / sub-panel |
BATTERIES (INTERNAL) | 2 x 12 V 12 AH | 2 x 12 V 12 AH |
OPERATING TEMPERATURE | -10ºC to 50ºC | -10ºC to 50ºC |
STORAGE TEMPERATURE | -10ºC to 50ºC | -10ºC to 50ºC |
HUMIDITY | Max 95% no condensation | Max 95% no condensation |
PROTECTION | IP21 | IP21 |
DIMENSIONS | 375 (L) x 345 (W) x 139 (H) mm | 420 (L) x 550 (W) x 127 (H) mm |
WEIGHT | 5,1 Kg (no batteries) | 8,1 Kg (no batteries) |
COLOUR | White or Red | White or Red |
ORDER CODE | ||
J-NET-EN54-SC-001 | 1 LOOP - PSU 2.4A | |
J-NET-EN54-SC-002 | 2 LOOPS - PSU 2.4A | |
J-NET-EN54-SC-003 | 3 LOOPS - PSU 2.4A | |
J-NET-EN54-SC-004 | 4 LOOPS - PSU 5A |
Description
JUNO NET MAIN PANEL
JUNO NET is a powerful Analogue Addressable Fire Alarm Control System with networking capabilities that facilitate the configuration of complex Wide Area Fire Detection Systems.
Modular construction and distributed intelligence allow systems of up to 96 Loops to be constructed. With a high level of built-in redundancy and emergency back-up features, the JUNO NET is fully equipped to control the most complex installations.
Using its wide array of interfacing capabilities the JUNO NET is ideally placed to provide an efficient and effective solution to the logistics of protecting large institutions, Universities, Airports, industrial complexes etc. which may have many individual Fire Alarm systems but require central reporting and control can easily be accommodated by the advanced capabilities of the JUNO NET.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Global Fire Addressable Panel JUNO NET” Cancel reply
Related Products
-
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
-
0 out of 5
Honeywell Gent Conventional Heat Detector : Eco 1005
• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty -
0 out of 5
TS1000
Tripod turnstiles are compact and cost-effective entrance solutions. Designing for smooth and silent operation, reducing power consumption, wear and tear. It is suitable for areas with a high traffic.
The TS1000 series, our stainless steel compact version,offer high operating reliability in a small casework, ideal for sites where space is an issue. By receiving a signal from the access control system, or pushing button, it allows the entry of one person in a time. Entering into different directions are electronically controlled. Default mode is to lock the mechanism until a valid authorization signal is received. IIf you want to set one side free, you can adjust the mechanism. In case of emergency, the horizontal arm will drop to allow free passage.
-
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Conventional Smoke Detector GFE-C
Key Features
- Dual LEDs for 360º visibility
- Advanced detection and communication protocols
- Easy installation and maintenance
- Sleek low-profile housing
- Durable sensor head, no need for replacement
- SMD circuit board design. High quality and reliability guaranteed
- Sensor Base Option: Regular GFE Detector Base or Deep Base
Reviews