- Fully expandable system from 1-96 Loops with distributed intelligence for added security
- Up to 256 devices per loop (TBA)
- Up to 96 Loop sounders with 32 individually programmable addresses per Loop
- Compatible with major analogue addressable communications protocols
- 2 Fire output changeover relays and 1 Fault output relay (NC)
- Open collector outputs for Fire, Fault and pre-alarm remote indication
- 2 fully monitored sounder outputs on main panel and each sub panel
- Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
- Redundant network communication via RS485, TCP/IP & Fiber Optics
- 384 programmable zones
- 512 fully programmable sounder and I/O groups
- Event Log 2000 entries FIFO
- Backlit LCD display 4 row * 40 characters
- Multiple programming options, onboard keypad, Remote IR(optional), PS2 Keyboard and GFE Connector software
- Windows™ based PC Graphics package ODYSSEY for alarm management and reporting(Optional)
- Multiple Language support (menu selectable)
- MODBUS (ASCII & RTU) and BMS support
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
- Fully expandable system from 1-96 Loops with distributed intelligence for added security
- Up to 256 devices per loop (TBA)
- Up to 96 Loop sounders with 32 individually programmable addresses per Loop
- Compatible with major analogue addressable communications protocols
- 2 Fire output changeover relays and 1 Fault output relay (NC)
- Open collector outputs for Fire, Fault and pre-alarm remote indication
- 2 fully monitored sounder outputs on main panel and each sub panel
- Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
- Redundant network communication via RS485, TCP/IP & Fiber Optics
- 384 programmable zones
- 512 fully programmable sounder and I/O groups
- Event Log 2000 entries FIFO
- Backlit LCD display 4 row * 40 characters
- Multiple programming options, onboard keypad, Remote IR(optional), PS2 Keyboard and GFE Connector software
- Windows™ based PC Graphics package ODYSSEY for alarm management and reporting(Optional)
- Multiple Language support (menu selectable)
- MODBUS (ASCII & RTU) and BMS support
TECHNICAL SPECIFICATIONS | 1 - 4 LOOPS | 4 - 13 LOOPS |
LOOPS | 1 to 4 loops - Max 275 mA per loop | 4 to 13 loops - Max 275 mA per loop |
SOUNDER OUTPUTS | 2 at 28 V DC / 500 mA each | 4/6/8 24 V DC / 500 mA each |
AUX. RELAYS FIRE | 2 rated 50 VAC / DC 1A resistive | 2 rated 50 VAC / DC 1A resistive |
AUX. RELAY FAULT | 1 rated 50 VAC / DC 1A resistive | 1 rated 50 VAC / DC 1A resistive |
AUX SUPPLY OUTPUT | 28 V DC; 2x230 mA | 28 V DC; 2x230 mA |
ADDITIONAL OUTPUTS | Multiplexed up to 384 Zones | Multiplexed up to 384 Zones |
PRIMARY SUPPLY | 230 +10% -15% V AC | 230 +10% -15% V AC |
SECONDARY SUPPLY | 28 V DC Nominal | 28 V DC Nominal |
POWER SUPPLY RATING | 65 W (1-3 Loop) - 150 W (4 Loop) | 150 W (4-6 Loop) - 200 W (7-13 Loop) |
QUIESCENT CURRENT (NO DEVICES) | 130 mA (1-3 Loop) - 180 mA (4 Loop) | 130 mA + 90 mA / sub-panel |
BATTERIES (INTERNAL) | 2 x 12 V 12 AH | 2 x 12 V 12 AH |
OPERATING TEMPERATURE | -10ºC to 50ºC | -10ºC to 50ºC |
STORAGE TEMPERATURE | -10ºC to 50ºC | -10ºC to 50ºC |
HUMIDITY | Max 95% no condensation | Max 95% no condensation |
PROTECTION | IP21 | IP21 |
DIMENSIONS | 375 (L) x 345 (W) x 139 (H) mm | 420 (L) x 550 (W) x 127 (H) mm |
WEIGHT | 5,1 Kg (no batteries) | 8,1 Kg (no batteries) |
COLOUR | White or Red | White or Red |
ORDER CODE | ||
J-NET-EN54-SC-001 | 1 LOOP - PSU 2.4A | |
J-NET-EN54-SC-002 | 2 LOOPS - PSU 2.4A | |
J-NET-EN54-SC-003 | 3 LOOPS - PSU 2.4A | |
J-NET-EN54-SC-004 | 4 LOOPS - PSU 5A |
Description
JUNO NET MAIN PANEL
JUNO NET is a powerful Analogue Addressable Fire Alarm Control System with networking capabilities that facilitate the configuration of complex Wide Area Fire Detection Systems.
Modular construction and distributed intelligence allow systems of up to 96 Loops to be constructed. With a high level of built-in redundancy and emergency back-up features, the JUNO NET is fully equipped to control the most complex installations.
Using its wide array of interfacing capabilities the JUNO NET is ideally placed to provide an efficient and effective solution to the logistics of protecting large institutions, Universities, Airports, industrial complexes etc. which may have many individual Fire Alarm systems but require central reporting and control can easily be accommodated by the advanced capabilities of the JUNO NET.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Global Fire Addressable Panel JUNO NET” Cancel reply
Related Products
-
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
Global Fire Conventional Panel ORION 2-4-8
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
-
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control -
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
-
0 out of 5
Honeywell Gent Conventional Heat Detector : Eco 1005
• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty
Reviews
There are no reviews yet.