HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
Electrical specification
Mains supply voltage: 230Vac (-15%,+10%), 50Hz or 60Hz
Operating voltage: 26.4V to 29 Vdc
Wiring: 2 x (0,6 to 1,5) mm² max, shielded / Length = 1500m max
Batteries: 2 x 12V/7Ah
Autonomy without mains: 1 hours in alarm (command)
Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 5 A
Mechanical characteristics
Dimensions (mm) / weight (without batteries) 320 x 610 x 175 (h x w d) / 5Kg (without batteries)
Material/colour ABS 5V/RAL 7035
Climatic characteristics
Operating temperature / Storage temperature -10°C to 50°C
Operating relative humidity / Storage relative humidity 93% R.H./ 80% R.H.
Inputs/outputs
Base: Max number of points / Max number of zones 400 points/1000 zones
Base: Fire detection lines 2 loops or 4 open lines
Fire alarm management Alarm, pre alarm, alarm confirmation, hours management
day/night mode
Memory events Up to 2700 events with date and hours
Programmable outputs (fire alarm, fault, test zone, disabled
point...) 3 x free contact relay outputs 50V/0,3A
Programmable inputs (power. supply fault, reset, sounders
activation...)
2 x monitored inputs for external event management (fault,
reset...)
2 x monitored inputs on front panel
Serial communication ports
RS232 communication port programming with PC
RS422 communication port for Jbus protocol for graphic
monitoring
On front panel
RS232 for external printer
2 x RS485 communication port for remote front panel
(redundant communication)
Sounders line 2 x monitored outputs 30V/1A (for the 2 lines)
External power supply output 1 x 24V/0,5A
Internal options
C20R, 20 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R7P2, 7 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R12P2, 12 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
External options
ALPHA RE remote control and indicating panel Serial connection (from 1 to 20 panels)
Description
HEPHAIS 1600 NE is a control and indicating equipment (CIE) with zone and point address localization
using microprocessor-based technology. It is designed to meet the requirements of standards EN54-2
and EN54-4.
HEPHAIS 1600 NE is an interactive-addressable panel and it can manage up to 400 devices on 2
loops of detection or 128 addresses on 4 lines.
The panel is made of a basis CPU board and control front panel. Optional remote front panel, relay
module boards and sounder line splitter are also available.
With its new functionalities, HEPHAIS 1600 NE provides a flexible solution for all Fire Detection
Systems (FDS.
HEPHAIS 1600 NE is reliable and easy to use equipment. Associated to interactive 05 detectors range,
It is adapted to all types of required topologies and can manage up to 400 detectors or manual call
points, that can be equipped of short-circuit isolator.
Adapted to a large scale of application, HEPHAIS 1600 NE can answer to requirements of buildings like
hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office
buildings, back office centres, thanks to its various and numerous outputs allowing many signalling and
command orders.
Field configuration, scheduled sensitivity and the manual setting constitute very useful start up modes
which make HEPHAIS 1600 NE installation a quick and sure operation.
The software TELEHEPHAIS1600 (download data) allows to configure advanced functionalities and
exploit all the capacities of the panel up to 1000 zones and 256 command groups
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 1600 Addressable Panel” Cancel reply
Related Products
-
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display -
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software
Reviews
There are no reviews yet.